Process

Process Control and Automation

Provide information from process signals to a technician at input signal site. Sound alarm and deploy safety measures on overrange.

DL-40JANUS-PROCESS
DL-40JANUS-PROCESS + DR + PS1 + IP01 + AIC + OR12

Measures process inputs and retransmits them to a PLC or other upstream device. Setpoint relays provide instant safety response to overrange input.

Configure this setup

Electrical Measurement

Volts, Amps, Watts

Customer needs to directly measure current, voltage, or watts and display the value to their user.

Full application note →
SM-35-DCV
SM-35-DCV

Texmate's foundational product lines are all suited for reliable, long-term direct measurement applications.

Configure this setup

Power Analysis

Single-Phase Multi-Parameter Control

Traditional power monitoring requires multiple transducers to measure volts, amps, watts, and other electrical parameters.

Full application note →
DI-503E
DI-503E

One meter with single-phase input calculates all parameters. Relay outputs trip alarms or cut power to connected devices on reaching setpoint thresholds.

Configure this setup

Tank Level Gauge

Fuel Level Monitoring

Curved hull tanks produce non-linear sensor output. Accurate volume display requires linearization.

Full application note →
FI-B101D50E
FI-B101D50E

Linearizes the signal for true volume in liters. Bargraph goes orange at 20%, red at 10%.

Configure this setup

Auto/Manual Station

Swapping from PLC to Direct Control

Customer has a PLC controlling various processes but needs an operator to temporarily take manual control.

Full application note →
DI-503MAS
DI-503MAS + RRR + PS1 + IP01 + AIC + S6 + OR12

I-Series auto/manual station allows operator to use push buttons for temporary adjustment or fine tuning before resuming automatic control by the PLC

Configure this setup

Stress Testing

Beam Load & Displacement Analysis

Structural testing requires capturing peak load pressure and linear displacement at the exact moment of beam failure.

Full application note →
DI-50E
DI-50E + DR + PS1 + ISS9 + S2 + AIC + OR12

Displays and holds peak readings on two channels. Logs data at constant rate for rate-of-change calculation.

Configure this setup

Weighing

Crane Scale with Zero Offset Protection

Electromagnetic crane lifts scrap metal, but residue clings after release. Operators must zero frequently.

Full application note →
DI-50E
DI-50E + DR + PS1 + IS01

Displays weight and allows manual zeroing stored in non-volatile memory. Blocks zero adjustments beyond preset limit.

Configure this setup

Irrigation

Smart Water Management

Crop yield hinges on precise water allocation. Requires tracking solar radiation, wind, rainfall, and temperature.

Full application note →
DI-503E
DI-503E + RRR + PS1 + OR91

Calculates daily evapotranspiration from on-site sensors. Triggers irrigation when computed water deficit reaches threshold.

Configure this setup